Does cemented versus uncemented humeral stem fixation influence outcomes in primary reverse shoulder arthroplasty? An updated systematic review and meta-analysis
Shoulder & Elbow · 13 Nov 2026
Priority is the editorial-priority score. All scores are out of 100. Rigour is how well the study was done for its own design: 50 means nothing is known either way, and the design itself is not counted. Clinical is how far this paper should move patient care if its methods hold up: the most its design can claim, times the relevance of its question, times how clearly it answered. The size of a result is read only against a threshold the paper states itself.
Why it matters
Humeral stem fixation is a routine intraoperative choice in reverse shoulder arthroplasty for cuff arthropathy and proximal humerus fractures, and this review suggests that surgeon factors and bone quality, rather than expected outcome differences, can reasonably guide it.
The evidence
This updated systematic review and meta-analysis pooled 49 observational studies (21,420 shoulders) of primary reverse shoulder arthroplasty, 22 of which directly compared cemented with uncemented (press-fit) humeral stems. In those direct comparisons, the two fixation methods showed no significant differences in range of motion, ASES, Constant or pain scores, periprosthetic fracture, tuberosity healing, or all-cause revision (OR 0.98, 95% CI 0.64 to 1.48). Cemented stems showed less stress shielding but more radiolucency (OR 4.97) and borderline more stem loosening (OR 2.08), and certainty of evidence was low to very low.
All-cause revision: Odds ratio 0.98 (95% CI 0.64 to 1.48; ratio). The interval includes no difference. This does not establish equivalence or rule out an important effect.
Why this rigour score?
Meta-analysis of observational studiesNeutral starting point: 50, the same for every design
Raised the score
- Prospectively registered+13.6
- Comprehensive literature search+9.1
Lowered the score
No negative adjustments recorded.
Score capped at 64. A critical methodological failure for a review.
Methods at a glance
Recorded assessment- Comprehensive literature searchMet
- Risk of bias assessedMet
- Bias considered in synthesisMet
- Publication bias assessedMet
- Study exclusions justifiedNot met
- Prospective registrationMet
Not reported does not mean not done. Checks have different weights; this is not a count of boxes ticked.
See the full score breakdown
- Neutral starting point (every design)
- 50
- Prospectively registered
- +13.6
- Comprehensive literature search
- +9.1
- Risk of bias assessed in the included studies
- +9.1
- Risk of bias carried into the synthesis
- +6.8
- Publication bias assessed
- +6.8
- Methodological cap
- −31.5
- Final rigour score rounded
- 64 / 100
Rigour is how well the study was done for its own design. Every design starts at 50, which means nothing is known either way; 100 means every safeguard that applies to this design was shown. The points above are already scaled by how much this design can show: a check counts for more in a design with few applicable checks and for less in one with many. The design itself is not counted here: it sets the ceiling of the clinical score instead. Points are shown to one decimal place; the final score uses unrounded values.
Checklist from the stored appraisal. “Not met” describes the recorded criterion; it does not always produce a deduction. This overview supports reading the full study.
How the clinical score was reached
The question: 8/9. Three judgements of how much it matters to patients, which decision it informs and how closely it fits their care.
Patient consequence: moderate (2/3). A patient-experienced outcome of real but smaller or shorter-lived importance: early pain or function, speed of recovery, return to sport or work, minor complications, satisfaction, or a validated score at a short time point.
Decision relevance: high (3/3). The study compares the actual options a clinician chooses between (or a whole strategy), and its primary result directly indicates which to choose, or that they are interchangeable. A clinician could act on it without a further translation step.
Applicability: moderate (3/3). A recognisable practice population, but with a notable restriction: narrow eligibility, a single expert surgeon or centre, or an unusual protocol that would need adapting. Applicability only subtracts for a real mismatch, so moderate counts in full.
What it found: No difference found, precision unclear (×0.80). No difference was found, but nothing shows the study could have found one: no power calculation, an interval that still reaches the paper's own threshold for an important difference, or a review whose certainty is low or unrated. Treated as neutral.
The design ceiling: 70. The most a meta-analysis of observational studies can score here, however relevant its question and clear its answer. The design is counted here and nowhere else; rigour does not include it.
Clinical = 70 × 8/9 × 0.80 = 50.
For journal club
1.For an elderly patient with an osteoporotic four-part proximal humerus fracture undergoing reverse shoulder arthroplasty, how would you weigh cemented versus press-fit stem fixation given these findings on tuberosity healing, revision and radiographic changes?
2.Given that cemented stems showed more radiolucency and loosening while uncemented stems showed more stress shielding, how should radiographic follow-up schedules and patient counselling differ by fixation type?
Original publication title
Does cemented versus uncemented humeral stem fixation influence outcomes in primary reverse shoulder arthroplasty? An updated systematic review and meta-analysis