ArthroplastyCohort

Early national comparison of robotic versus conventional hip replacements for arthritis using National Joint Registry data: target trial emulation study

BMJ · 30 Sept 2026

Rigour55/100
Clinical44/100
Priority62/100

Priority is the editorial-priority score. All scores are out of 100. Rigour is a stored score from the earlier method, which included the study design; it has not been recalculated. Clinical is a stored clinical-importance score from the earlier method; it has not been recalculated.

Why it matters

Health systems are investing heavily in robotic hip replacement, and this early national evidence suggests no overall survivorship advantage so far, which matters for counselling patients and for decisions about where to spend resources.

The evidence

This national registry study compared robotic-assisted with conventional total hip replacement in about 666,000 UK operations from 2018 to 2024, using propensity score matching to create comparable groups (9,915 robotic vs 39,660 conventional). After matching, revision risk over a mean of 2.5 years did not differ (hazard ratio 0.96, 95% CI 0.75 to 1.22), with five year implant survival of 98.8% in both groups. Revisions for malposition-related causes (dislocation, leg length discrepancy, malalignment) were less common after robotic surgery (HR 0.53, 95% CI 0.30 to 0.93), and mortality did not differ.

All cause revision (implant survival): Hazard ratio 0.96 (95% CI 0.75 to 1.22; ratio). The interval includes no difference. This does not establish equivalence or rule out an important effect.

How strong would a hidden confounder have to be? This comparison was not randomised. To explain the association away, something the study did not account for would need to be tied to both the exposure and the outcome by a risk ratio of about 1.25; the interval already includes no difference. This is the E-value. The estimate is an odds or hazard ratio read as a risk ratio, which overstates this when the outcome is common. It is shown for context and is not part of any score.

Why this rigour score?

Target trial emulationStored score from the earlier method, which included the study design

55/ 100

Methods at a glance

Recorded assessment
  • Confounding adjustmentPropensity scores
  • Covariate balance confirmedNot met
  • Outcome assessors blindedMet
  • Comparable start of follow-upMet
  • Adequate statistical powerNot reported
  • Prospective registrationNot met

Not reported does not mean not done. Checks have different weights; this is not a count of boxes ticked.

How to read this assessment

This score was calculated by an earlier version of the method, in which the study design set the starting point and the ceiling. It has not been recalculated, so no point-by-point breakdown is shown. The current method measures how well a study was done for its own design and starts every design at the same neutral value.

Checklist from the stored appraisal. “Not met” describes the recorded criterion; it does not always produce a deduction. This overview supports reading the full study.

For journal club

1.If robotic THR lowers malposition-related revisions but not overall revision, which patients (for example, those at high dislocation risk) might benefit most from robotic assistance?

2.How should a surgeon counsel a patient who asks for robotic hip replacement, given similar early implant survival but higher costs?

Original publication title

Early national comparison of robotic versus conventional hip replacements for arthritis using National Joint Registry data: target trial emulation study

Read original paper