Foot & AnkleCohort

Headless Compression Screws May Reduce Symptomatic Hardware After Medial Malleolus Fixation: A Comparative Cohort Study

Journal of Orthopaedic Trauma · 9 Oct 2026

Rigour31/100
Clinical57/100
Impact†48/100

† Impact is the editorial-priority score. All scores are out of 100. Clinical is a stored clinical-importance score from the earlier method; it has not been recalculated.

Why it matters

Symptomatic hardware is one of the commonest complications after ankle fracture fixation, and implant choice over the subcutaneous medial malleolus is a modifiable decision that trainees will see daily.

The evidence

This single-centre retrospective study compared two kinds of screws for fixing medial malleolus (ankle) fractures in 306 adults: headless compression screws, which sit below the bone surface, and standard headed screws. Medial-sided hardware irritation was documented in 23 of 111 patients (20.7%) with headless screws versus 68 of 195 (34.9%) with headed screws, an adjusted odds ratio of 0.55 (95% CI 0.32 to 0.96). Rates of hardware removal (23.4% vs 30.8%), nonunion and infection did not differ significantly. Every headless screw came from a single surgeon, so the screw effect cannot be separated from that surgeon's technique.

Symptomatic hardware (medial-sided hardware irritation): Odds ratio 0.55 (95% CI 0.32 to 0.96; ratio). The interval favours the first group; the size of the benefit needs clinical interpretation.

Why this rigour score?

Retrospective cohortDesign starting point: 29.6

31/ 100

Raised the score

  • Compared against current standard of care+3.4

Lowered the score

  • A single centre's own patients−3.4

Methods at a glance

Recorded assessment
  • Confounding adjustmentMultivariable regression
  • Covariate balance confirmedNot applicable
  • Outcome assessors blindedNot reported
  • Comparable start of follow-upNot reported
  • Adequate statistical powerNot reported
  • Prospective registrationNot met

Not reported does not mean not done. Checks have different weights; this is not a count of boxes ticked.

See the full score breakdown
Study design starting point
29.6
Compared against current standard of care
+3.4
A single centre's own patients
−3.4
Journal prior (not an observed method)
+1.4
Final rigour score rounded
31 / 100

Study design sets the starting point and a ceiling of 72. Recorded methods then adjust the score. Points are shown to one decimal place; the final score uses unrounded values.

Checklist from the stored appraisal. “Not met” describes the recorded criterion; it does not always produce a deduction. This overview supports reading the full study.

For journal club

1.Given that headless screws lowered documented irritation but did not significantly reduce hardware removal surgery, how would you counsel a thin patient with a medial malleolus fracture about implant choice and the likelihood of a second operation?

2.In an older patient with osteoporotic bone, would you still choose a headless compression screw over a headed screw that can buttress the fragment, and how would that choice affect your follow-up plan?

Original publication title

Headless Compression Screws May Reduce Symptomatic Hardware After Medial Malleolus Fixation: A Comparative Cohort Study

Read original paper